Parameter
22 MITSUBISHI ELECTRIC
Function Parameter Meaning Setting range Default
Calibration
functions
C1
(901)
AM terminal calibration Calibration range
C2
(902)
Frequency setting voltage bias frequency 0–60Hz 0Hz
C3
(902)
Frequency setting voltage bias 0–300% 0%
C4
(903)
Frequency setting voltage gain 0–300% 96%
C5
(904)
Frequency setting current bias frequency 0–60Hz 0Hz
C6
(904)
Frequency setting current bias 0–300% 20%
C7
(905)
Frequency setting current gain 0–300% 100%
C8
(269)
Parameter set by manufacturer: Do not set!
Clear
functions
CLr Clear parameter
0: Do not clear parameter
1: Clear parameter
10: Clear all parameters
0
ECL Clear alarm history
0: Do not clear alarm history
1: Clear alarm history
0
Parameters only for the type having the RS-485 communication function
(When the parameter unit (FR-PU04) is used, operation from the operation panel is not accepted.)
Communi
-
cation
functions
n1
(331)
Station number 0–31 0
n2
(332)
Communication speed
48: 4800 Baud
96: 9600 Baud
192: 19200 Baud
192
n3
(333)
Stop bit length / data length
0 / 1: Data length 8
10 / 11: Data length 7
1
n4
(334)
Parity check
0: Absent
1: With odd parity check
2: With even parity check
2
n5
(335)
Number of communication retries 0–10 / --- 1
n6
(336)
Communication check time interval 0–999s / --- ---
n7
(337)
Wait time setting 0–150ms / --- ---
n8
(338)
Operation command write
0: Command write from
computer
1: Command write
from external terminal
0
n9
(339)
Speed command write
0: Command write from
computer
1: Command write
from external terminal
0
n10
(340)
Link start mode selection
0: As set in Pr. 79
1: Started in computer link
operation mode.
0