Mitsubishi MOTION CONTROLLERS Q172DCPU Manuale delle Istruzioni Pagina 100

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 316
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 99
4 - 69
4 POSITIONING DEDICATED SIGNALS
4.2.7 Cam axis monitor devices
(1) Execute cam No. storage register (D1241+10n) ... Monitor device
(a) This register stores the cam No. currently being controlled.
(b) Cam No. of the execute cam No. storage register is held until next cam is
executed. (Cam No. is not cleared, even if cam control is completed.)
(2) Execute stroke amount storage register (D1242+10n, D1243+10n)
.........….. Monitor device
(a) This register stores the cam No. currently being controlled.
(3) Current value within 1 cam shaft revolution storage register
(D1244+10n, D1245+10n) ....................................... Monitor device
(a) This register stores the current value within 1 cam shaft revolution set in the
parameter.
The current value is a ring address of "0 to [Number of pulses per cam shaft
revolution (Nc)-1]".
0
(N
C
-1)
Vedere la pagina 99