Vedere la pagina 188
8 - 4
8 OUTPUT MODULE
REMARK
(Note) : The operation cycle is set in the "operation cycle setting" of system basic
setting.
Refer to the "Q173DCPU/Q172DCPU Motion controller Programming
Manual (COMMON)" for details.
The operation cycle of Motion CPU is shown below.
Item Q173DCPU Q172DCPU
Number of control axes Up to 32 axes Up to 8 axes
Operation cycle
(Default)
SV22
0.44[ms] / 1 to 4 axes
0.88[ms] / 5 to 12 axes
1.77[ms] / 13 to 28 axes
3.55[ms] / 29 to 32 axes
0.44[ms] / 1 to 4 axes
0.88[ms] / 5 to 8 axes
Vedere la pagina 188